大香蕉毛片视频免费下载_91香蕉小视频在线观看_WWW香蕉视频APP_香蕉视频黄软件-亚洲欧美日韩国产成人在线_日韩中文字幕无码一区二区_

產(chǎn)品中心

人成纖維細(xì)胞生長(zhǎng)因子21(FGF21)酶聯(lián)免疫吸附檢測(cè)試劑盒
ELK1323
規(guī)格: 價(jià)格:
48T ¥1680.00
96T ¥2400.00

Overview 文獻(xiàn)

Product name: Human FGF21(Fibroblast Growth Factor 21) ELISA Kit
Reactivity: Human
Alternative Names: Fgf21; FGF-21
Assay Type: Sandwich
Sensitivity: 4.2 pg/mL
Standard: 500 pg/mL
Detection Range: 7.82-500 pg/mL
Sample Type: serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
Assay Length: 3.5h
Research Area: Cytokine;
Uniprot ID: Q9NSA1
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Human FGF21. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Human FGF21. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Human FGF21, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human FGF21 in the samples is then determined by comparing the OD of the samples to the standard curve.

標(biāo)準(zhǔn)曲線

Concentration (pg/mL) OD Corrected OD
500.00 2.166 2.070
250.00 1.764 1.668
125.00 0.980 0.884
62.50 0.699 0.603
31.25 0.527 0.431
15.63 0.372 0.276
7.82 0.262 0.166
0.00 0.096 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant FGF21 and the recovery rates were calculated by comparing the measured value to the expected amount of FGF21 in samples.
Matrix Recovery range Average
serum(n=5) 88-103% 95%
EDTA plasma(n=5) 92-106% 99%
Heparin plasma(n=5) 90-105% 97%

線性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of FGF21 and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 88-97% 90-99% 85-97% 79-101%
EDTA plasma(n=5) 78-94% 97-105% 88-101% 82-96%
Heparin plasma(n=5) 89-102% 79-94% 83-96% 85-106%