大香蕉毛片视频免费下载_91香蕉小视频在线观看_WWW香蕉视频APP_香蕉视频黄软件-亚洲欧美日韩国产成人在线_日韩中文字幕无码一区二区_

產(chǎn)品中心

人神經(jīng)激肽B(NKB)酶聯(lián)免疫吸附檢測(cè)試劑盒
ELK1801
規(guī)格: 價(jià)格:
48T ¥1960.00
96T ¥2800.00

Overview 文獻(xiàn)

Product name: Human NKB(Neurokinin B) ELISA Kit
Reactivity: Human
Alternative Names: NK-B; TAC3; NKNB; ZNEUROK1; Neuromedin K; Tachykinin 3; Neurokinin Beta
Assay Type: Competitive Inhibition
Sensitivity: 3.19 pg/mL
Standard: 800 pg/mL
Detection Range: 12.5-800 pg/mL
Sample Type: Serum, plasma and other biological fluids.
Assay Length: 2h
Research Area: Neuro science;Hormone metabolism;
Uniprot ID: Q9UHF0
Test principle: This assay employs the competitive inhibition enzyme immunoassay technique. The microtiter plate provided in this kit has been pre-coated with Human NKB. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Human NKB. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human NKB in the samples is then determined by comparing the OD of the samples to the standard curve.

標(biāo)準(zhǔn)曲線

Concentration (pg/mL) OD Corrected OD
800.00 0.175
400.00 0.352
200.00 0.577
100.00 0.895
50.00 1.139
25.00 1.578
12.50 1.813
0.00 2.101

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant NKB and the recovery rates were calculated by comparing the measured value to the expected amount of NKB in samples.
Matrix Recovery range Average
serum(n=5) 78-93% 85%
EDTA plasma(n=5) 82-95% 88%
Heparin plasma(n=5) 89-103% 96%

線性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of NKB and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 95-104% 79-92% 82-95% 86-97%
EDTA plasma(n=5) 85-92% 89-103% 97-105% 91-99%
Heparin plasma(n=5) 86-97% 90-98% 80-93% 92-105%